RFXtrx Version 4.14 page 25 / 35
7.4. Energenie 5-gang 429.950
To know the codes to use open the remote and check the 1 to 5 jumpers connected.
If a jumper connection is open it is a 1. If connected it is a 0 (zero)
1 2 3 4 jumper setting in the remote
HC=========
A 0 0 0 0
B 0 0 0 1
C 0 0 1 0
D 0 0 1 1
E 0 1 0 0
F 0 1 0 1
G 0 1 1 0
H 0 1 1 1
I 1 0 0 0
J 1 0 0 1
K 1 0 1 0
L 1 0 1 1
M 1 1 0 0
N 1 1 0 1
O 1 1 1 0
P 1 1 1 1
If jumper 5 is open (1) than add 5 to the remote code.
Examples:
Jumper Button Code
1 2 3 4 5
1 0 0 0 0 1 I1
1 0 0 0 1 1 I6